Personal tools
You are here: Home Hardware SAS Controller LSI 2208 LSI 2208 on Supermicro X9DRH-7TF (AdpAllInfo)

LSI 2208 on Supermicro X9DRH-7TF (AdpAllInfo)

The following is a cpture of 'AdpAllInfo' on the controller from FreeBSD v9.1/Nas4Free.

# CmdTool2_64 -AdpAllInfo -a 0

Adapter #0

==============================================================================
                    Versions
                ================
Product Name    : Supermicro SMC2208
Serial No       :
FW Package Build: 23.9.0-0015

                    Mfg. Data
                ================
Mfg. Date       : 00/00/00
Rework Date     : 00/00/00
Revision No     :
Battery FRU     : N/A

                Image Versions in Flash:
                ================
BIOS Version       : 5.37.00_4.12.05.00_0x05180000
WebBIOS Version    : 6.1-49-e_49-Rel
Preboot CLI Version: 05.05-03:#%00011
FW Version         : 3.220.05-1881
NVDATA Version     : 2.1209.03-0112
Boot Block Version : 2.05.00.00-0009
BOOT Version       : 07.26.13.219

                Pending Images in Flash
                ================
None

                PCI Info
                ================
Vendor Id       : 1000
Device Id       : 005b
SubVendorId     : 15d9
SubDeviceId     : 0690

Host Interface  : PCIE

ChipRevision    : D1

Number of Frontend Port: 0
Device Interface  : PCIE

Number of Backend Port: 8
Port  :  Address
0        4433221100000000
1        4433221101000000
2        4433221102000000
3        4433221103000000
4        4433221104000000
5        4433221105000000
6        4433221106000000
7        4433221107000000

                HW Configuration
                ================
SAS Address      : 5003048010a5b400
BBU              : Absent
Alarm            : Present
NVRAM            : Present
Serial Debugger  : Present
Memory           : Present
Flash            : Present
Memory Size      : 1024MB
TPM              : Absent
On board Expander: Absent
Upgrade Key      : Absent
Temperature sensor for ROC    : Present
Temperature sensor for controller    : Absent

ROC temperature : 49  degree Celcius

                Settings
                ================
Current Time                     : 11:41:46 5/23, 2013
Predictive Fail Poll Interval    : 300sec
Interrupt Throttle Active Count  : 16
Interrupt Throttle Completion    : 50us
Rebuild Rate                     : 30%
PR Rate                          : 30%
BGI Rate                         : 30%
Check Consistency Rate           : 30%
Reconstruction Rate              : 30%
Cache Flush Interval             : 4s
Max Drives to Spinup at One Time : 2
Delay Among Spinup Groups        : 12s
Physical Drive Coercion Mode     : 1GB
Cluster Mode                     : Disabled
Alarm                            : Enabled
Auto Rebuild                     : Enabled
Battery Warning                  : Disabled
Ecc Bucket Size                  : 15
Ecc Bucket Leak Rate             : 1440 Minutes
Restore HotSpare on Insertion    : Disabled
Expose Enclosure Devices         : Enabled
Maintain PD Fail History         : Disabled
Host Request Reordering          : Enabled
Auto Detect BackPlane Enabled    : SGPIO/i2c SEP
Load Balance Mode                : Auto
Use FDE Only                     : No
Security Key Assigned            : No
Security Key Failed              : No
Security Key Not Backedup        : No
Default LD PowerSave Policy      : Controller Defined
Maximum number of direct attached drives to spin up in 1 min : 10
Any Offline VD Cache Preserved   : No
Allow Boot with Preserved Cache  : No
Disable Online Controller Reset  : No
PFK in NVRAM                     : No
Use disk activity for locate     : No

                Capabilities
                ================
RAID Level Supported             : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60,
                                   PRL 11, PRL 11 with spanning, SRL 3 supported, 
                                   PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
Supported Drives                 : SAS, SATA

Allowed Mixing:

Mix in Enclosure Allowed
Mix of SAS/SATA of HDD type in VD Allowed
Mix of SAS/SATA of SSD type in VD Allowed
Mix of SSD/HDD in VD Allowed

                Status
                ================
ECC Bucket Count                 : 0

                Limitations
                ================
Max Arms Per VD          : 32
Max Spans Per VD         : 8
Max Arrays               : 128
Max Number of VDs        : 64
Max Parallel Commands    : 1008
Max SGE Count            : 60
Max Data Transfer Size   : 8192 sectors
Max Strips PerIO         : 42
Max LD per array         : 16
Min Strip Size           : 8 KB
Max Strip Size           : 1.0 MB
Max Configurable CacheCade Size: 0 GB
Current Size of CacheCade      : 0 GB
Current Size of FW Cache       : 0 MB

                Device Present
                ================
Virtual Drives    : 0
  Degraded        : 0
  Offline         : 0
Physical Devices  : 9
  Disks           : 8
  Critical Disks  : 0
  Failed Disks    : 0

                Supported Adapter Operations
                ================
Rebuild Rate                    : Yes
CC Rate                         : Yes
BGI Rate                        : Yes
Reconstruct Rate                : Yes
Patrol Read Rate                : Yes
Alarm Control                   : Yes
Cluster Support                 : No
BBU                             : Yes
Spanning                        : Yes
Dedicated Hot Spare             : Yes
Revertible Hot Spares           : Yes
Foreign Config Import           : Yes
Self Diagnostic                 : Yes
Allow Mixed Redundancy on Array : No
Global Hot Spares               : Yes
Deny SCSI Passthrough           : No
Deny SMP Passthrough            : No
Deny STP Passthrough            : No
Support Security                : No
Snapshot Enabled                : No
Support the OCE without adding drives : Yes
Support PFK                     : Yes
Support PI                      : Yes
Support Boot Time PFK Change    : No
Disable Online PFK Change       : No
Support LDPI Type1                      : No
Support LDPI Type2                      : No
Support LDPI Type3                      : No
PFK TrailTime Remaining         : 0 days 0 hours
Support Shield State            : Yes
Block SSD Write Disk Cache Change: Yes

                Supported VD Operations
                ================
Read Policy          : Yes
Write Policy         : Yes
IO Policy            : Yes
Access Policy        : Yes
Disk Cache Policy    : Yes
Reconstruction       : Yes
Deny Locate          : No
Deny CC              : No
Allow Ctrl Encryption: No
Enable LDBBM         : Yes
Support Breakmirror  : No
Power Savings        : No

                Supported PD Operations
                ================
Force Online                            : Yes
Force Offline                           : Yes
Force Rebuild                           : Yes
Deny Force Failed                       : No
Deny Force Good/Bad                     : No
Deny Missing Replace                    : No
Deny Clear                              : No
Deny Locate                             : No
Support Temperature                     : Yes
Disable Copyback                        : No
Enable JBOD                             : Yes
Enable Copyback on SMART                : No
Enable Copyback to SSD on SMART Error   : Yes
Enable SSD Patrol Read                  : No
PR Correct Unconfigured Areas           : Yes
Enable Spin Down of UnConfigured Drives : Yes
Disable Spin Down of hot spares         : No
Spin Down time                          : 30
T10 Power State                         : No
                Error Counters
                ================
Memory Correctable Errors   : 0
Memory Uncorrectable Errors : 0

                Cluster Information
                ================
Cluster Permitted     : No
Cluster Active        : No

                Default Settings
                ================
Phy Polarity                     : 0
Phy PolaritySplit                : 0
Background Rate                  : 30
Strip Size                       : 64kB
Flush Time                       : 4 seconds
Write Policy                     : WB
Read Policy                      : Adaptive
Cache When BBU Bad               : Enabled
Cached IO                        : Yes
SMART Mode                       : Mode 6
Alarm Disable                    : Yes
Coercion Mode                    : 1GB
ZCR Config                       : Unknown
Dirty LED Shows Drive Activity   : No
BIOS Continue on Error           : No
Spin Down Mode                   : None
Allowed Device Type              : SAS/SATA Mix
Allow Mix in Enclosure           : Yes
Allow HDD SAS/SATA Mix in VD     : Yes
Allow SSD SAS/SATA Mix in VD     : Yes
Allow HDD/SSD Mix in VD          : Yes
Allow SATA in Cluster            : No
Max Chained Enclosures           : 16
Disable Ctrl-R                   : Yes
Enable Web BIOS                  : Yes
Direct PD Mapping                : No
BIOS Enumerate VDs               : Yes
Restore Hot Spare on Insertion   : No
Expose Enclosure Devices         : Yes
Maintain PD Fail History         : No
Disable Puncturing               : No
Zero Based Enclosure Enumeration : No
PreBoot CLI Enabled              : Yes
LED Show Drive Activity          : Yes
Cluster Disable                  : Yes
SAS Disable                      : No
Auto Detect BackPlane Enable     : SGPIO/i2c SEP
Use FDE Only                     : No
Enable Led Header                : No
Delay during POST                : 0
EnableCrashDump                  : No
Disable Online Controller Reset  : No
EnableLDBBM                      : Yes
Un-Certified Hard Disk Drives    : Allow
Treat Single span R1E as R10     : No
Max LD per array                 : 16
Power Saving option              : Don't Auto spin down Configured Drives
Max power savings option is  not allowed for LDs. Only T10 power conditions are to be used.
Default spin down time in minutes: 30
Enable JBOD                      : No
TTY Log In Flash                 : No
Auto Enhanced Import             : No
BreakMirror RAID Support         : No
Disable Join Mirror              : No
Enable Shield State              : Yes
Time taken to detect CME         : 60s

Exit Code: 0x00